Patternator Results - 2012


Complete Statistics

Percent Coverage of Red Dye with Various Papers using DepositScan (3rd test)

7.5 feet above ground
Treatment Mean
gloss 22.48% a
semi-gloss 24.95% a
matte 20.60% a
water sensitive paper 37.08%     b
matte 1% level of significance
gloss & semi-gloss 5% level of significance
7.0 feet above ground
gloss 28.78% a 5% level of significance
semi-gloss 33.10% a   b
matte 33.28% a   b
water sensitive paper 41.55%     b
6.5 feet above ground
gloss 39.50% a no significant difference
semi-gloss 36.18% a
matte 38.70% a
water sensitive paper 54.45% a
6.0 feet above ground
gloss 35.03% a no significant difference
semi-gloss 38.50% a
matte 33.85% a
water sensitive paper 46.63% a
5.5 feet above ground
gloss 38.50% a   b 5% level of significance
semi-gloss 42.98% a   b
matte 36.85% a
water sensitive paper 53.03%     b
5.0 feet above ground
gloss 45.73% a 1% level of significance
semi-gloss 48.48% a
matte 48.93% a
water sensitive paper 60.78%     b
4.5 feet above ground
gloss 40.45% a 1% level of significance
semi-gloss 44.88% a
matte 40.90% a
water sensitive paper 62.18%     b
4.0 feet above ground
gloss 42.80% a 1% level of significance
semi-gloss 46.68% a
matte 47.23% a
water sensitive paper 62.10%     b
3.5 feet above ground
gloss 51.03% a
semi-gloss 51.70% a
matte 57.03% a
water sensitive paper 69.05%     b
gloss & semi-gloss 1% level of significance
matte 5% level of significance
3.0 feet above ground
gloss 43.55% a no significant difference
semi-gloss 44.30% a
matte 42.15% a
water sensitive paper 59.73% a
2.5 feet above ground
gloss 25.50% a no significant difference
semi-gloss 20.13% a
matte 19.23% a
water sensitive paper 26.18% a
2.0 feet above ground
gloss 16.45% a no significant difference
semi-gloss 15.25% a
matte 11.93% a
water sensitive paper 12.60% a
1.5 feet above ground
gloss 7.50% a no significant difference
semi-gloss 5.43% a
matte 4.80% a
water sensitive paper 3.23% a
1.0 feet above ground
gloss 1.85% a no significant difference
semi-gloss 1.25% a
matte 1.23% a
water sensitive paper 1.33% a
treatments with different letters are significantly different (Tukey's hsd test)